A11VO75DR/10L-NPC12N00: Swashplate-type variable displacement piston pump with a displacement of 75 cm³/rev, and it is equipped with the pressure compensation (DR control) function as a standard configuration.
A11VO95LG2/10L-NSD12N00: With a displacement of 95 cm³/rev, it integrates the load sensing (LG2 control) and pressure cut-off functions, and is suitable for complex working conditions.
Performance Indicators
Maximum working pressure: The continuous working pressure is 350 bar, and the peak pressure is 400 bar.
Speed range: Under standard working conditions, it is 1500~2500 rpm, and the ultimate speed is 2800 rpm (an auxiliary booster pump needs to be configured).
Volumetric efficiency: ≥ 95% (under the rated pressure).
Control Characteristics
DR control (A11VO75): Achieves constant pressure output through external adjustment, and is suitable for open circuit systems.
LG2 control (A11VO95): A composite control mode that integrates the flow demand signal and power limitation, and supports the collaborative operation of multiple actuators.